Simply sort out the relevant construction technology of the interlayer of the steel structure workshop, you need to get it yourself.Warm reminders are for reference only, specific matters need to be analyzed in detail and combined with the actual situation.What kind of building is a steel structure mezzanine? Rationally use the original building space to build a mezzanine floor with just decoupled strands.By changing the layout, the space can be used more, but the steel structure interlayer is difficult, and the design and construction are troublesome.The construction process of the interlayer of most steel structure workshops is as follows: (1) Confirm whether there are additional conditions for the steel structure interlayer on site, check the position of the structure, beam, column and wall according to the original structural drawing, confirm the anchor point, measure the actual size, and prepare for accounting; (2) Establish an accounting model, confirm the load requirements according to the application function, and calculate the member section and the deflection value of the steel structure interlayer; (3) Check whether the surrounding members meet the future stress requirements for increasing the steel structure interlayer; if not satisfied, the next step will be based onAccounting results to develop reinforcement plans.Construction stage: Material preparation The first is to purchase data such as section steel according to the calculated standard quantity.According to the planning drawings, cutting, grinding, welding structural components, etc.On-site construction According to the mezzanine planning drawings, locate and lay out the line on site, and confirm the size of the pre-buried location.Pre-embedded equipment According to the actual chemical bolt hole position, drill holes on the pre-embedded steel plate and channel steel (section steel), and then the equipment will pre-embed the steel plate.There are three different laying materials on the steel structure interlayer, such as pressure steel plate, light floor load-bearing plate, wood plank.Anti-rust treatment The steel structure workshop shall carry out rust-removal treatment on all steel structural components, and brush the anti-rust paint to maintain and dry.Apply fire retardant paint.When erecting the interlayer, the first and foremost is safety, and there should be no situations such as insufficient stress, shaking, and excessive deflection.Secondly, after erecting the steel structure interlayer, try to ensure enough clear height to meet the use requirements.Section steel processing The scale is re-measured on site and the section steel is processed.Main beam equipment The main steel beam is welded and connected with the embedded steel plate according to the positioning of the line to ensure the smoothness of the steel beam.The steel structure manufacturer welds the main steel beam and the round beam according to the planning drawings.According to the building structure, plan the addition of floors to ensure that it is within the bearing range of the foundation.In the planning of steel structure mezzanine, the following three principles should also be ensured: (1) Try not to damage the original structure; (2) Pay attention to the lighting settings.Generally speaking, steel structure attics are characterized by insufficient light, large scattered floor heights, and irregular space. The planning should pay special attention to the deployment and setting of lighting to ensure that there is light in every place, and light cannot be abused; (3) Rational use of space.In a word, when planning the interlayer of the steel structure of the manufacturing equipment, the specific bearing capacity of the interlayer of the house, the application requirements and the reasonable selection of the interlayer material should be considered.At the same time, the characteristics of each laying material of the steel structure mezzanine are different, especially considering the bearing capacity of the house mezzanine, so when deciding to plan the workshop or office building mezzanine, it is necessary to require professional relevant personnel to carry out accurate measurement and evaluation, and formulate careful and detailedThe plan is strictly in accordance with the technical requirements for construction to ensure the safe use of the steel structure interlayer.The above is the construction process of the mezzanine of the steel structure workshop. Do you understand it after reading it?